Building entries

Multi-line building entries

Multi-line building entries

MSH PolySafe, MSH Basic and MSH-FW Basic are our universal modular design multiple-service building entry systems for district heating. They bring together numerous benefits in a single solution: one trench, one core drill, one building entry, but four lines. As well as providing a compact and reliable entry point for supply lines, they support in particular the setting up of a single empty conduit system from the inside of the building to the street outside. This provides a platform for retrofitting additional entries for multimedia/communication supplies and other cable-bound power sources, for example, without further excavation work being necessary.

Our patented torque display, plus the addition of an integrated leak test, ensure maximum installation reliability. A simple test procedure following installation checks that the connection to the building is tight. Thanks to our multiple-service building entry systems, you will not only save yourself time but also space and hassle.

Through the wall - wall still to be concreted

Universal wall sleeve

for any type of wall

UFR
Enables sealing in all types of wall when combined with sealing flange and 3-bridge seals.

Through the wall - wall already exists

Basic variant with inner seal

for buildings with a basement

MSH PolySafe GV1
Gastight and watertight building entry for gas, water, power and telecommunications services. Basic variant 1 …

Basic variant with inner seal

for buildings with a basement

MSH PolySafe GV2
Gastight and watertight building entry for gas, water, power and telecommunications services. Basic variant 2 …

Basic variant for wet installation

for buildings with a basement

MSH PolySafe MV
Gastight and watertight building entry for gas, water, power and telecommunications services. Grouting with …

Basic variant with inner seal for district heating

for buildings with a basement

MSH FW Basic GV1
Gastight and watertight building entry for district heating, water, power and telecommunications services. …

Basic variant with inner seal for district heating

for buildings with a basement

MSH FW Basic GV2
Gastight and watertight building entry for district heating, water, power and telecommunications services. …

Slab

Multi-line basic insert, arranged side by side

For buildings without a basement

MSH Basic FUBO SR4 EBT
For the collective feeding in and sealing of all supply lines (power, water, telecommunications, gas) through …

Seal insert for basic insert

arranged side by side

MSH Basic MBK R4
Gastight and watertight building entry for buildings without a basement for the collective feeding in of …

Multi-line basic insert, arranged side by side

For buildings without a basement

MSH Basic FUBO SR3 EBT
For the collective feeding in and sealing of all supply lines (power, water, telecommunications or gas) …

Multi-line basic insert, arranged side by side

For buildings without a basement

MSH Basic FUBO SR2 EBT
For the feeding in and sealing of supply lines (power, water, telecommunications or gas) through the base …

Seal insert for basic insert

arranged side by side

MSH Basic MBK SR3
For the collective feeding in and sealing of all supply lines (power, water, telecommunications, gas) for …

Wall entry pipe bend 160

for district heating lines

MSH Basic FUBO-FIX RB160
For the feeding in and sealing of district heating supply lines through the floor slab. Positioning with …

Seal insert for basic insert

arranged side by side

MSH Basic MBK SR2
For the collective feeding in and sealing of all supply lines (power, water, telecommunications, gas) for …

Wall entry pipe bend 200

for district heating lines

MSH Basic FUBO-FIX RB200
For the feeding in and sealing of district heating supply lines through the floor slab. Positioning with …